“General” Tab

Position | Designation | Description | |
---|---|---|---|
1 | Formula Management in the PLC | Disables the following options: “Save Formula,” “Load Formula” and “Overwrite Existing Formula on Download.” | |
A POU (Programming Organization Unit) is created in the runtime system for formula management. | |||
2 | Save Formula | ||
Automatically Save Formula Changes to the Formula Files | Does not automatically save changes. | ||
Automatically saves formulas to a file after a change. | |||
3 | Load Formula | ||
Only Load If Variable List Matches Exactly | Loads a formula file only if it contains all the variables from the list of variables of an application’s formula definition. | ||
Load Variables with Matching Names | All matching variable names are loaded from the formula file. Note: | ||
4 | Overwrite Existing Formulas on Download | Existing formulas are not overwritten when a new application is initialized. | |
Existing formulas may be overwritten when a new application is initialized. | |||
5 | Write Formula | ||
Limit Variable to Min/Max | If the formula contains a value outside the value range entered in the definition, the specified minimum or maximum value is written to the PLC variable instead of this value. | ||
Do Not Write Variable If Formula Outside Min/Max Range | If the formula contains a value that is outside the value range entered in the definition, no value is written to the PLC variable. It retains its current value. | ||
6 | Check Formula for Changes | Formula is saved without additional checks. | |
Generates additional code to save a formula only if it is changed by using “ReadAndSaveRecipe.” | |||
7 | Tooltips | Moving the mouse over one of the elements listed above causes an additional tooltip to appear at this point. |